Category: MA-Series

(Results from 21 to 30)
What is the break away point for MA lever spindle?
The lever spindles for the MA have a breaking torque of 45-55 ft-lb....
Schlage Commercial » Mechanical Locks » Mortised » MA-Series
What are the differences between S76806 and S76816 Falcon part numbers?
Part number S76806 are spindles used with levers on standard door thickness of 1 3/4 to 1 7/8" or knobs with a door thickness of 1 7/8 to 2 1/2". Part number S76816 are spindles used for le...
Schlage Commercial » Mechanical Locks » Mortised » MA-Series
Will Schlage L9000 mortise trim fit on a Falcon MA mortise lock?
Falcon MA trim will not fit on L9000 mortise locks, nor will Schlage L9000 trim fit on Falcon MA mortise locks. ...
Schlage Commercial » Mechanical Locks » Mortised » MA-Series | Schlage Commercial » Mechanical Locks » Mortised » L9000 Series
Can the electrified MA handing be changed?
The Request to Exit (RX) on the MA851 or MA881 monitors both sides and does not require Rehanding....
Schlage Commercial » Mechanical Locks » Mortised » MA-Series
What door prep is required for Falcon Single Dummy MA12 with rose trim?
The Falcon MA12 Single Dummy trim does not have a lock body thus no mortise pocket.The following holes should be drilled based on the trim type:For rose (sectional) trim, drill the hole for lever spin...
Schlage Commercial » Mechanical Locks » Mortised » MA-Series
What door prep is required for the Falcon Double Dummy MA18 with rose trim?
The Falcon MA18 Double Dummy trim does not have a lock body thus no mortise pocket.The following holes should be drilled based on the trim type:For rose (sectional) trim, drill the holes for lever mou...
Schlage Commercial » Mechanical Locks » Mortised » MA-Series
Is the Falcon MA series mortise locks available in 613 finish?
The 613 Oil-Rubbed finish was discontinued for the Falcon MA mortise locks in February 2025. ...
Schlage Commercial » Mechanical Locks » Mortised » MA-Series
What is the difference between the Falcon M and MA series mortise locks?
M is discontinued and was replaced by the MA.Here are some of the major differences between the M and MA-Series. Lever mounting post holes -  Locations have changed on door template.  (...
Schlage Commercial » Mechanical Locks » Mortised » MA-Series
Do Falcon MA series locks have Florida Building Code (FBC) approval for Hurricane non-impact on pair doors?
MA Series Assembly Florida Building Code approvals for MA pairs with non-impactPair Flush Doors - FL10356.1Pair Glazed Doors - FL10356.4Pair Louvered Doors - FL10356.5...
Schlage Commercial » Mechanical Locks » Mortised » MA-Series
What is the Minimal Stile requirements for Falcon Locksets?
The Falcon T series was discontinued August 12th, 2026 and was replaced by the Falcon TM series. ...
Schlage Commercial » Mechanical Locks » Cylindrical » B Series (Falcon) | Schlage Commercial » Mechanical Locks » Cylindrical » T Series (Discontinued) | Schlage Commercial » Mechanical Locks » Cylindrical » W Series | Schlage Commercial » Mechanical Locks » Deadbolts » D Series (Falcon) | Schlage Commercial » Mechanical Locks » Mortised » MA-Series