Will our PS 900 series work with a third-party battery back up?
 No, The Battery has to be a 7-amp hour sealed lead acid battery otherwise the charging current is wrong...
Schlage Commercial » Power Supplies » Standard » PS900 Series
How to tell if a PS902, 904,906 and 914 are working correctly?
There should be a green LED AC side and red LED DC side of the main board. You can see the green AC led with the box cover closed but have to open the cover to see the red LED for DC....
Schlage Commercial » Power Supplies » Standard » PS900 Series | Schlage Commercial » System Components » Power Supplies » PS900 Series
Using a 900-4RL with an AO setting, how does this work?
For both sides to work together yes. Relay 1 actuates the locking device and 2 sends the dry contact signal to the AO. Relay 3 actuates the locking device on the second door and 4 sends the dry contac...