Category: Falcon

(Results from 51 to 60)
Can the Von Duprin Rod Guard (RGO) be used on Falcon Surface Vertical Rod devices?
Von Duprin Rod Guards (RGO's) can be used on Falcon 24-V, 25-V, 19-V, and XX-V devices.They cannot be used on WS98/9927 or WS98/9957 devices....
Schlage Commercial » Exit Devices » Mechanical Accessories | Schlage Commercial » Falcon | Schlage Commercial » Von Duprin
I need to replace a 24R that did not have deadlatching. What do I order?
24 R new center case #650234-00 and new cover #650249  (specify finish).   ...
Schlage Commercial » Falcon
What does the 3H mean on a Falcon B or Falcon H lock?
The 3H stamped into the face plate of the Falcon B and Falcon H lock means 3-hour fire rated. ...
Schlage Commercial » Falcon
Are there results or ratings of a salt spray test on a 25 series?
The device must meet minimum of 100 hrs., standards:  ASTM  B117Falcon organic finishes (powder-coat, e-coat, etc.) are only certified to 96 hours.  Falcon inorganic finishes such as ch...
Schlage Commercial » Falcon
What type of cylinder does a Falcon 812L trim use?
A rim cylinder is required for rim and vertical rod XX devices.  A mortise cylinder is required for a mortise lock XX device....
Schlage Commercial » Exit Devices | Schlage Commercial » Falcon
For an older 18 R Apollo NL trim, what would I use to replace with current product?
You could use:Falcon: 25 R 512NL,  or Von Duprin: 98NL 990....
Schlage Commercial » Exit Devices | Schlage Commercial » Falcon | Schlage Commercial » Von Duprin
Is the Falcon 25V exit device handed?
The device is handed but field reversible as shown here in step 11 of the installation instructions....
Schlage Commercial » Exit Devices | Schlage Commercial » Falcon
Does the 2' 9927-F come with a fire lable?
Yes...
Schlage Commercial » Exit Devices | Schlage Commercial » Falcon
Will the F-25-R work for a 9' tall door? The catalog says only good to 8'.
8' max  height on UL fire rated F-25-R...
Schlage Commercial » Exit Devices | Schlage Commercial » Falcon
Is the LM or DM switch for the 25 series available as a field installable kit?
For the 25 series, the LM or DM kit is field replaceable, but not field installable.  There are 2 holes that must be drilled in the center case at the factory for those switch kits....