Can the EL conversion kits for the Falcon 24/25 Series be used on the Monarch 17/18 Series?
Resolution:
No, the EL conversion kits for the Falcon 24/25 Series are too big to fit into the Monarch 17/18 Series devices.:
How do you specify a Schlage mortise cylinder with a competitor cam?
Resolution:
For example, if looking for a Full Size IC core cylinder with a Yale cam, first find a part number for a FSIC cylinder with a straight cam, such as 26-091. Then select the Yale cam from...:
Can a Falcon mortise cylinder thumbturn be used on an MA lock?
Resolution:
Thumbturn cylinders and cointurn cylinders are not recommended on Falcon MA mortise locks. If the thumbturn or cointurn is rotated halfway and left out of position, this can cause a bind...:
LCN RAL custom powder coat color chart?
Resolution:
See here for the LCN RAL custom powder coat color chart. :
Where do you find the Falcon 8200 instruction sheets?
Resolution:
See here.:
Are the 4631 and 4642 hydraulic cylinders the same?
Resolution:
The 4631 hydraulic cylinder (4631-3971 cylinder only) and the 4642 hydraulic cylinder (4642-3971 cylinder only) are not the same as the internal components are assembled differently. So they ...:
Is the electrified L9000 PCB still available?
Resolution:
The electrified L9000 PCB (L283-344) is no longer available and there is no replacement. Complete lock chassis must be ordered.:
What is the minimum height of a 377T used with an 8827 or 8827-F device?
Resolution:
With the 8827 or 8827-F device mounted at the standard centerline of 39 13/16" above the finished floor, the centerline of the thumbturn can be located at 46 1/2” above the finished floor minimum.:
Can the Schlage D-series be converted from conventional cylinder to full size interchangeable core?
Resolution:
Using kit 04-030, you can convert the Schlage D-series from a conventional cylinder prep (PD) to a full size interchangeable core prep (JD). Using kit 04-034, you can convert the S...:
What size security bit would be used with the X Mount option?
Resolution:
The X Mount security mounting option for Ives pulls is a "pin in star" design that is 5/16" diameter with an 1/8" pin in the middle.:
«