Question
Answer
What is holding force for CL11 or CL 12 ?
Resolution:
There is no tested holding force available for the CL11 or CL12 cabinet latch. These devices are designed to latch a regular cabinet or light weight door ( such as closet or pantry). &nbs...:
Is a plastic cushion included with all automatic door bottoms (ADB) ?
Resolution:
Yes, a plastic cushion is included with all screw packs shipped with Automatic Door Bottoms. This cushion is used to minimize marking on a wood frame.:
Can the VR900 be mounted back to back with some kind of pushplate on inside or push side of door?
Resolution:
No, the studs on the VR900 do not align with exit device mounting patterns.:
Can an F-25-V be cut down to 28"?
Resolution:
No.The 24/25 catalog states the shortest length that a 3' 25 series device can be cut is 31-1/8".For additional information, please contact Allegion product support at 877-671-701...:
What is the latch throw for the HL6?
Resolution:
The throw or project of the HL6 tubular latch is 1/2". :
What are the details about 900-KL, 900 series power supply locks?
Resolution:
Cam locks for the 900 series (902/904/906/914) power supplies can be ordered with the power supply or as a separate item. The model number for the lock is 900-KL, and the part number is 44486...:
What is the part number for the set screw for the SL1/SK1 inside ligature trim?
Resolution:
The set screw part number for the inside SL1/SK1 ligature trim is L583-585.The size of the Allen wrench needed to install the set screw is 5/64". :
What is the part number for the hex nut for the 945 Falcon Cam Lock?
Resolution:
The hex nut part number for the 945 Falcon Cam Lock is 031100-000-30. :
Is the QEL Polarized?
Resolution:
No. The power wires to the QEL are not polarized.(Screenshot taken from Installation Instructions):
Why is there a transient voltage suppressor included with my electric strike?
Resolution:
ANSI BHMA 156.13 has a provision for inductive kickback. Using the transient suppressor across the strike's solenoid wires allows this standard to be met. This would be most applicable ...:
«