When did LCN change the DPS Switch on the 2210DPS series closers from a 10.1 amps rated switch to one with an .1mA rated switch?
Resolution:
LCN changed the DPS switch on the 2210DPS series closers from a 10.1 amp rated switch to a .1mA rated switch on February 23rd, 2018.Photo of DPS switch as 2/23/2018 see here. Note the tr...:
Can a thumbturn cylinder be used on the L9453?
Resolution:
A thumbturn cylinder will not provide the intended operation. The L9453 requires the actual thumbturn hub to be rotated the additional 20° to unlock the outside lever once the deadbolt has be...:
What is the temperature range of the 4200 electric strike?
Resolution:
The 4200 electric strike has been tested by the supplier to: -35 to 65 degree Celsius (-31 to 149 degree Fahrenheit) The strike has also been tested to U...:
What size of the 94 impact device would be used on a 2'10" door?
Resolution:
The standard 94/95 device was designed to fit door openings from 2’-10” to 4’-0”, not net door sizes. Originally, the shorter version of the Inpact device was designed to fit door openings fro...:
Is there a part number for the Von Duprin plastic template?
Resolution:
900594-00 is the correct part number for the plastic template that ships with the 98/99 exit device:
Can the pushbar armor "PA" be ordered separately for existing devices?
Resolution:
Yes.Order: PA-PBKIT-98 (or 99) x size and finishPlease contact Allegion support for additional details. Call 877-671-7011, option 2, then 3.:
Do we offer a longer spring for the 410S?
Resolution:
No, but a piece of aluminum bar stock in the track in front of the spring is ok.Installer will need to position door where they want it , and then measure the length of block they will n...:
What is the replacement part number for the round neoprene gasket on a 8878AA?
Resolution:
It's the 8303S-BK:
Can you clarify sizing information for 94/95 devices?
Resolution:
The standard 94/95 device is designed to fit door openings from 2’-10” to 4’-0”, not net door sizes. Long-time customers may recall that the shorter version of the Inpact device originally was desi...: