Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
FAQs
«
665
666
667
668
669
»
Question
Answer
Can a pair of 6300 electric strikes be used with a mullion? Is the 6300 electric strike fire rated for pairs of doors?
Resolution:
The 6300 electric strike is only fire rated (UL10C, 3 hour) for single door applications.For non-fire rated openings, a pair of 6300 strikes can be used on a Von Duprin steel (not aluminum) mullion...:
What is the maximum undercut for the LM9300 series?
Resolution:
Since Schlage does not dictate what type of threshold can be used with the LM9300, the maximum undercut should not be less than 1/8" and not greater than 3/4". The bottom rod should have a 1/2...:
What is the part number for the E996 trim cable for Allegion Connect (CON) applications?
Resolution:
The package number is 106183. It includes a 4' cable that feeds through the exit device. One end has a receptacle to connect to the E996 solenoid wire plug. The oth...:
What grade of stainless steel are the 7100/7200 pivots?
Resolution:
304 grade:
Is a blade stop shim available for the 6300 electric strike?
Resolution:
Von Duprin does not offer a 1/2" blade stop shim for the 6300 strike. It is furnished standard with a 1/16" shim. Additional 1/16" shims can be ordered separately as part #050804.:
Schlage Custom Series: Remove Knob or Lever
Resolution:
All Schlage Custom Series knobs and levers are secured with an Allen set screw. Use the Allen wrench provided with your lock to remove the set screw.To Remove the Set ScrewLocate the Set Screw.Unfa...:
What cylinder and cam are required for the Falcon 718C-C and 718NL-C cylinder control for 24 and 25 series concealed vertical rod exit devices?
Resolution:
Last updated 10/12/2020 The 718C-C & 718NL-C Falcon control trims use 1-1/4" mortise cylinder with a narrow cam. The following chart applies to 718C-C & 718NL-C control...:
Can the LM9200 be installed into an aluminum door?
Resolution:
Not a recommended application due to the amount of material removed from the door as well as the special support brackets needed for the top and bottom latches.:
Can Falcon MA581 mortise lock be used with Von Duprin 6223 electric strike?
Resolution:
They are compatible. The center line of the MA latch bolt should be lined up with the center line of 6223 strike. Another way to look at it is, CL of the MA lock body is ¼”above the C...:
Do double door delayed egress applications (Chexit or DE5300) require both devices to unlock when either device releases?
Resolution:
The codes do not specifically include a requirement for both leaves of a pair with delayed egress locks to unlock when one device is actuated. Even though the codes don’t specifically ...:
«
665
666
667
668
669
»